Deflexio Verticalis |
|
Numerus canalium |
2 |
Bandwidth |
100 MHz |
Tempus surgens |
3.5 ns |
Architectura Canalis |
Omnibus input integre divisae ab invicem et a terra Input possunt activari in qualibet combinatione |
Coesio Input |
Alternans vel Directa, cum indicatore livelli terrae |
Input sensus |
Cum probe 10:1, 20 mV ad 1000 V/div Cum probe 100:1, 200 mV ad 10 kV/div Directum (1:1), 2 mV ad 100 V/div |
Limitator Largitatis |
20 MHz et 10 kHz |
Polaritas |
Normale, inversum, variabile |
Resolutio Verticalis |
8 bit |
Accuracy ad 4 s ad 10 μs/div |
5 mV/div ad 100 V/div, ±(1.5% + 6 computa) 2 mV/div, ±(1.5 % + 10 computa) |
Input impedimentum |
1 MΩ (±1 %) // 15 pF (±2.25 pF) |
Input voltage range |
|
Censitus Maximus Voltius Fluctuantis |
CAT III 1000 V \ CAT IV 600 V (voltium maximus inter quemlibet contactum et terra-terra voltii level) |
Ingressus Probæ VPS410-II |
CAT III 1000 V \ CAT IV 600 V (voltium maximus inter standardem probam 10:1 et referentiam lineam) |
Ingressus Probæ VPS421 |
CAT III 1000V / CAT IV 600V (maxima voltus inter extremum probae aut conductorem referentem ad GND, 2000V maxime inter extremum probae et conductorem referentem conductorem) |
Maxima Voltus Input BNC |
CAT IV 300 V (maxima voltus in input BNC directe) |
Maxima Voltus in Input Metri |
CAT III 1000 V \ CAT IV 600 V (connectores input banana ad securitatem descripti) |
Memoria Salva et Recurre |
|
Loci Memoriae (Interni) |
30 memoriae formae undarum plus 10 memoriae recording plus 9 memoriae copiae schermi |
30 Memoriae Formae Undarum |
Unaquaeque memoria potest continere usque ad 2 vel 4 formas undarum plus correspondentes arrangementes |
10 Memoriae Recensenda |
Unusquisque potest continere: ordinem Reproductionis Schermi 100, aut registrationem modi Roll ScopeRecord (2 vel 4 vestigia), aut TrendPlot registrationem usque ad 4 mensuras |
Externum Conservandum Datorum |
In Computatro, per FlukeView™-2 Software, vel directum conservandum in externo disco memoriae flash (maxime 32 GB) per portam USB host |
Imagines ex raptu |
In computatro, utendo FlukeView™-2 Software, aut interna (in instrumento) quae transfertur ad externam memoriam flash per portam USB .BMP-fasciculus, per portam USB hospitalem |
Volatilitas |
Servatio fit in Flash-ROM non volatili et omnes data secura sunt, independentes a statu acumuli vel potentiae |
Real-time horologium |
Praebet informationem de tempore et die pro ScopeRecord, pro 100 sequentiis Repraesentationis Scenae et pro registrationibus TrendPlot |
Causa |
|
Designatio |
Robustus, praeservativus cum integrato futterali. Funis et alligatura manuum inclusi standarditer Serratura Kensington supportata ad claudendum instrumentum quando non est attentum |
Immunis a stillatibus et pulvere |
IP 51 secundum IEC60529 |
Percussio et Vibratio |
Impulsus 30 g, vibratio (sinusoidalis) 3 g / 0.03 g2/Hz (Aleatorius), iuxta MIL-PRF-28800F Classis 2 |
Ostentationis magnitudo |
5.3 x 3.5" (133 x 90 mm) LCD |
Resolutio |
1120 pixes x 765 pixes |
Claritas |
A utente regulabilis, usque ad 300 cd/m2 |
Specificationes generales |
|
Temperatura |
Operatio: congeries descaricanda: 32 ad 104°F (0 ad 40°C); congeries caricanda: 0 ad 40°C (32 ad 104°F) Deposita: -4 ad 140°F (-20 ad 60°C) |
Humiditas |
32 ad 50°F (0 ad 10°C): non condensans 50 ad 86°F (10 ad 30°C): 95% (±5%) 86 ad 104°F (30 ad 40°C): 75% (±5%) 104 ad 122°F (40 ad 50°C): 45% (±5%) |
Altissima Altitude Operationis |
CAT IV 600 V, CAT III 1000 V: usque ad 6600’ (2000 m) CAT IV 300 V, CAT III 600 V, CAT II 1000 V: usque ad 13000’ (4000 m) |
Altissima Altitude Storing |
40,000’ (12 km) |
Interficia |
Duobus portis USB praebentur Portus plene ab instrumento insulantur a circuite mensura fluitante Portus USB-host directe conectitur ad memoriam externam flash (usque ad 32 GB) pro stogage datis undarum, resultatis mensurae, configuratio instrumenti et copiae schermatis Alternatim, hic portus USB-A potest uti ad conectendum Adapter WiFi pro connectione PC sine filo Fertur portus mini-USB-B qui permittit interconnectionem ad PC pro remota controllo et translatio datorum sub PC-controllo FlukeView-2. |
Calibratio Probæ Output |
Probæ-cal output dedicatus cum contactu referentiam praebente, omnino ab omni canalium input mensura insulatus Generator Output: 1.225 Vpp / 500 Hz unda quadrata |
Linea Potentia |
Universalis adaptator praecipuum/cursitorium cum acumine BC190/830 inclusus, cum duobus separabilibus filis alimentationis 100 VAC ad 240 VAC, ±10%, 50 ad 60 Hz |
Altilium |
Vires: renovabilis batteria Li-Ion; batteriam mutabilis per faciliter accessibilem januam batteriae in posteriori parte instrumenti Genus: BP290: 10.8V, 2500 mAh Indicium incendi: batteria cum indicatore statuti inserto ad usum cum externo incenditore, iuxta indicatorem status batteriae in schermo instrumenti Tempus operationis (cum retroilluminatione minima): usque ad 3½ horas utendo BP290 Tempus incipiendi: 2½ horarum utendo BP290; 5 horarum utendo BP291 Functiones servandi vim: Automata ‘vim deorsum’ cum tempore vim deorsum accomodabili; automatica ‘off display’ cum tempore vim deorsum accomodabili tempus; indicium vim batteriae in schermo |
Dimensiones |
10.5 x 7.6 x 2.8" (265 x 192 x 70 mm) |
Pondus |
4.6 libras (2.1 kg) |