Resistance Measurement Range |
3 mΩ (max. display 3.100 mΩ, resolution 1 μΩ) to 3 Ω (max. display 3.100 Ω, resolution 1 mΩ), 4 ranges Accuracy: ±0.8 % rdg ±6 dgt (3 mΩ range: ±1.0 % rdg ±8 dgt) Testing source frequency: 1 kHz ±30 Hz With function for avoiding noise frequency enabled: 1 kHz ±80 Hz Testing current: 160 mA (3m/30 mΩ range), 16 mA (300 mΩ range), 1.6 mA (3 Ω range) Open terminal Voltage: 5 V peak |
Voltage Measurement Range |
±6 V (maximum display ±6.000 V, resolution: 1 mV) to ±60 V (maximum display ±60.00 V, resolution: 10 mV), 2 ranges, Accuracy: ±0.08% rdg ±6 dgt |
Temperature Measurement Accuracy |
Measurement range: 14 to 140°F (-10 to 60°C) Maximum display: 140.0°F (60.0°C) Resolution 0.1°F (0.1°C) Measurement accuracy: ±1.8°F (±1.0°C) * When using the Clip Type Lead with Temperature Sensor 9460. * When using the Temperature Probe 9451, add ±0.9°F (±0.5°C) (cable length: 59.1" [1.5 m]). * When using the Temperature Probe 9451S, add ±0.9°F (±0.5°C) (cable length: 3.94" [0.1 m]). BT3554-50 standalone accuracy with simulated input: ±0.9°F (±0.5°C) |
Absolute Maximum Input Voltage |
60 V DC maximum (no AC input) |
Measurement Time |
100 ms |
Response Time |
Approximately 1.6 seconds |
|
Compares measured values with set threshold values to make judgments and reports them to the user. Judgment notification method: Results are displayed as shown below (segment) and beeping tones sound When the Voltage value (high): Resistance value (low)= PASS, Resistance value (medium)= WARNING, Resistance value (high)= FAIL When the Voltage value (low): Resistance value (low)= WARNING, Resistance value (medium)= WARNING, Resistance value (high)= FAIL If the judgment result is WARNING or FAIL, the audio tone is accompanied by a red backlight. User-selectable voltage judgment method: ABS (absolute value judgment), POL (polarity judgment ) Savable settings: 200 tables |
|
Operation: Save, load, and delete measurement data, Save and delete profile information, Number of data sets: 6000, Memory architecture: 500 data sets per unit (12 units) Saved data: Saved measurement data is linked to profile information. 1. Measurement data: Data can be saved, loaded, and deleted by operating the instrument. -1. Date and time -2. Resistance value, voltage value, and temperature -3. Comparator threshold value and judgment result 2. Profile information: Profile information can be saved, loaded, and deleted using a supported application (GENNECT Cross or GENNECT One). -1. Profile numbers: 1 to 100 (Data (2), (3), and (4) below are saved for each profile number) -2. Location: User-defined comment such as location of UPS -3. Device information: User-defined comment such as UPS management number -4. Battery number: 1 to 500 (start number, end number) |
|
Operation: Announces the next battery number to be measured via a screen display and audio guidance Preparations: Profile information that's been registered with a supported application (GENNECT Cross or GENNECT One) must be transferred to the instrument |
Communication Interface |
USB |
Other Functions |
Temperature measurement -10 to 60°C (14 to 140°), zero-adjustment, hold, auto-hold, auto-memory, auto-power-save, clock |
Power Supply |
8 x LR6 (AA) alkaline dry battery Continuous operating time: About 8.3 hours |
Dimensions |
7.83 x 5.20 x 2.39" (199 x 132 x 60.6 mm) (with protector) |
Weight |
33.9 oz (960 g) (including batteries and protector) |