Ambitus temperaturae infrarubrae |
−40 ad 1202 °F (−40 ad 650 °C) |
Accuracy Infrarubrum |
<32 °F (0 °C): ±(2,0 °F (±1,0 °C) + 0,1°/1 °F aut °C) >32°F (0°C): ±1% vel ±2.0°F (±1.0°C), quodcumque maius est |
Propono resolutio |
0.1°F (0.1°C) |
Responsio Spectralis Infrarubra |
8 to 14 µm |
Tempus Responsionis Infrarubræ |
<500 msec |
Ambitus Temperaturæ Input Typi-K Thermocoppæ |
-454 ad 2501°F (-270 ad 1372°C) |
Thermocouple Typus-K Input Accuratia |
−454 ad −40 (−270 ad −40 °C): ±(2 °F + 0,2°/1 °F) (±[1 °C + 0,2°/1 °C]) −40 ad 2501,6 °F (−40 ad 1372 °C): ±1 % aut 2 °F (±1 % aut 1 °C), quodcumque maius sit |
Distantia ad locum mensurae |
30:1 |
Designatio Laseris |
Unus-punctus laser <1 mw exitus Classis 2 (II) operatio, 630 ad 670 nm |
Minimus Puncti Magnitudo |
0.75" (19 mm) |
Ajustamentum Emissivitatis |
Per tabulam integratam materialem communem aut digitaliter adjustibilis ab 0.10 ad 1.00 per 0.01 |
Deposito Datorum cum Nota Datae/Horae |
20 puncta |
Interfacing cum Computatro et Funis |
Nulla |
Alarumae Summa/Ima |
Audibilis et bicolores visuales |
Min/Max/Avg/Dif |
Ita |
Display |
Punctum matricis 98 x 96 pixes cum functionibus menu |
Backlight |
Duae gradationes, normalis et praetermodum clarum pro nigrioribus ambiantibus |
Clavis Tractus |
Ita |
Commutabilis Celsius et Fahrenheit |
Ita |
Potentia |
2 bateriae AA/LR6 |
Vita Altilium |
Laser et lucerna posterior accensae, 12 horae (continuo usurpatae) Laser et lucerna posterior exstinctae, 100 horae (continuo usurpatae) |
Temperatura operativa |
32 ad 122°F (0 ad 50°C) |
Temperatura recondita |
-40 ad 140°F (-20 ad 60°C) |
Globus Thermocopus Typi-K Ambitus |
-40 ad 500°F (-40 ad 260°C) |
Globus Thermocopus Typi-K Accuratudo |
±2.0°F (1.1°C) ab 32 usque ad 500°F (0 usque ad 260°C), saepe intra 2.0°F (1.1°C) ab -40 usque ad 32°F (-40 usque ad 0°C) |