Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000
Products
Home> Products

Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC

Product Description
Make testing faster and safer, all without touching a live conductor using FieldSense technology. Get accurate voltage/current measurements by clipping the black test lead to any electrical ground, put the clamp jaw around the conductor, and see the displayed results. Features power quality indicator to show whether a problem is in the equipment or the power line.
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC supplier
378 FC 1000 A AC/DC True-RMS Non-contact Voltage Wireless Clamp W/ Power Quality Indicator, IFLEX
* True RMS AC/DC clamp meter
* Make basic power quality measurements and rule out power quality issues in these three categories: PQ-Volts, PQ-Amps and PQ-PF
(Power Factor)
* CAT Rating: CAT III 1000V; CAT IV 600V
* Capacitance Resistance: 999.9 µF/ 60 Ω
* Voltage AC/DC: 1000 V/1000 V
* Current AC/DC: 2500 A/1000 A
* FieldSense voltage: 1000V
* 3 Phase measurement
* View both Voltage and current measurements simultaneously on dual display
* Field-sense enables Voltage measurements without connecting to any live conductors
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC factory


Fluke 378 FC - Non-Contact Voltage True-RMS AC/DC Clamp Meter with iFlex and Power Quality Indicator

* True-RMS AC/DC clamp meter
* Includes Power Quality Indicator
* CAT Rating: CAT III 1000V; CAT IV 600V
* Capacitance/Resistance: 999.9 µF/ 60 Ω
* Voltage AC/DC: 1000 V/1000 V
For the first time, make non-contact voltage measurement with an industrial clamp meter, accurately and safely, without connecting to live conductors. Improve your workflow efficiency for 3-phase measurements and use the Power Quality indicator to screen for Power Quality related issues.

The Fluke-377 FC and Fluke-378 FC Clamp Meters have four unique capabilities that set them apart from other clamp meters:
Uses Field-Sense™ technology to make testing faster and safer, all without touching a live conductor, and provides accurate voltage and current measurements through the clamp jaw. Easily clip the black test lead to any electrical ground, put the clamp jaw around the conductor, and see reliable, accurate voltage and current values on the display.
What's included with the Fluke 378FC
* Clamp Meter
* Flexible Probe
* ToolPak™ Magnetic Meter Hanger
* Test Leads
* TwistGuard™ Test Probes
* Black Grounding Clip
* Premium Carrying Case
* Quick Reference Guide
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC details
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC factory
Specification
Current

AC - Jaw
Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)
Crest factor (50/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. >2

AC - Flexible Current Probe
Range: 2500 A
Resolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)
Accuracy: 3% ±5 digits (5 to 500 Hz)
DC
Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% ±5 digits
Voltage

AC - FieldSense
Range: 1000 V
Resolution: 1 V (≤1000 V)
Accuracy: ≤4/0 AWG - 3% ±5 digits (45 to 66 Hz); ≥4/0 AWG - 5% ±5 digits (45 to 66 Hz)

AC - Test Leads
Range: 600.0 V, 1000 V
Resolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)
Accuracy: 1% ±5 digits (20 to 500 Hz)
DC
Range: 600 V, 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% ± 5 digits
mV DC
Range: 500 mV
Resolution: 0.1 mV
Accuracy: 1% ±5 digits
Amps Frequency

Jaw
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% ±5 digits
Trigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A

Flexible Current Probe
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% ±5 digits
Trigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A
Other Measurements

Resistance
Range: 60 kΩ, 6000 Ω, 600 Ω
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)
Accuracy: 1% ±5 digits

Capacitance
Range: 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)
Accuracy: 1% ±4 digits
General Specifications
General Maximum Voltage
1000 V (between any terminal and earth ground)
Battery
Type: 2 x AA IEC LR6 alkaline
life: 200 hours
Display
Dual readout
Automatic Power Off
20 minutes
Temperature
Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Operating Humidity (Without Condensation)
Non condensing (<50°F [<10°C])
≤90% RH (50 to 86°F [10 to 30°C])
≤75% RH (86 to 104°F [30 to 40°C])
≤45% RH (104 to 122°F [40 to 50°C])
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C >28°C or <18°C
Ingress Protection
IEC 60529: IP30 (jaw closed)
Altitute
Operating: 6561.68' (2000 m)
Storage: 39,370.1' (12,000 m)
Electromagnetic Compatibility (EMC)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103

Safety
General: IEC 61010-1: Pollution degree 2
Measurement: IEC 61010-2-032: CAT III 1000 V/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V

Wireless Radio
Radio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE
Frequency range: 2405 to 2480 MHz
Output power: <100 mW


Dimensions
10.78 x 3.38 x 1.85" (274 x 86 x 47 mm)
Jaw opening: 1.34" (34 mm)
Flexible current probe diameter: 0.29" (7.5 mm)
Flexible current probe cable length: 5.9' (1.8 m)
Rogowski coil length: 17.71" (450 mm)
Weight
1 lbs (463 g) with batteries
Packing & Delivery
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC supplier
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC factory
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC supplier
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC manufacture
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC factory
Fluke 378FC Digital Clamp Meter with IFlex and Power Quality Indicator Non Contact Detection of AC and DC manufacture
FAQ
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing...
So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop