* Offers an ultra-high 60:1 distance-to-spot ratio with dual laser sighting for fast, accurate targeting
* Features a user-selectable multi-language interface
Infrared Measurements |
||
Temperature Range |
-22 to 1652°F (-30 to 900°C) |
|
IR Accuracy (calibration geometry with ambient temperature 23°C ±2°C) |
≥32°F: ±2°F or ±1% of the reading, whichever is greater ≥14°F to <32°F: ±4°F <14°F: ±6°F ≥0°C: ±1°C or ±1 % of the reading, whichever is greater ≥-10°C to <0°C: ±2°C <-10°C:±3 °C |
|
IR Repeatability |
±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
|
Display Resolution |
0.1°F/0.1°C |
|
Distance:Spot |
60:1 (calculated at 90% energy) |
|
Minimum Spot Size |
0.75" (19 mm) |
|
Laser Sighting |
Offset dual laser, output <1 mW |
|
Spectral Response |
8 µm to 14 µm |
|
Response Time (95%) |
<500 ms |
|
Emissivity |
Digitally adjustable from 0.10 to 1.00 by 0.01 or via built-in table of common materials |
|
Contact Measurements |
||
K-Type Thermocouple Input Temperature Range |
-454 to 2501°F (-270 to 1372°C) |
|
K-Type Thermocouple Input Accuracy |
<-40°F: ±(2°F + 0.2°/1°F) ≥-40°F: ±1% or 2°F, whichever is greater <-40°C: ±(1 °C + 0.2°/1°C) ≥-40°C: ±1% or 1°C, whichever is greater |
|
K-Type Thermocouple |
0.1°F/0.1°C |
|
K-Type Thermocouple Repeatability |
±0.5% of reading or ±1°F (±0.5°C), whichever is greater |
|
Measurement Options |
||
Hi/Low Alarms |
Audible and two-color visual |
|
Min/Max/Avg/Dif |
Yes |
|
Switchable Celsius and Fahrenheit |
Yes |
|
Backlight |
Two levels, normal and extra bright for darker environments |
|
Probe Input |
K-type thermocouple simultaneous display of probe and IR temperature |
|
Trigger Lock |
Yes |
|
Data Storage |
99 points |
|
Display |
Dot matrix 98 x 96 pixels with function menus |
|
Communication |
USB 2.0 |
|
K-Type Thermocouple Specifications |
||
Measurement Range (Bead Probe) |
-40 to 500°F (-40 to 260°C) |
|
Accuracy |
±2.0°F (±1.1°C) from 32 to 500°F (0 to 260°C) Typically within 2.0°F (1.1°C) from -40 to 32°F (-40 to 0°C) |
|
Cable Length |
40" (1 m) K-type thermocouple cable with standard miniature thermocouple connector and bead termination |
|
General Specifications |
||
Safety and Compliance |
IEC 60825-1 FDA Laser Class II IEC 61326-1 CE Complaint CMC # 01120009 |
|
Operating Temperature |
32 to 122°F (0 to 50°C) |
|
Storage Temperature |
-4 to 140°F (-20 to 60°C) |
|
Relative Humidity |
10 to 90% RH non-condensing up to 86°F (30°C) |
|
Operating Altitude |
2000 meters above mean sea level |
|
Weight |
0.7099 lb (0.322 kg) |
|
Power |
2 x AA batteries |
|
Battery Life |
8 hours with laser and backlight on; 100 hours with laser and backlight off, at 100 % duty cycle (thermometer continuously on) |