Get a Free Quote

Our representative will contact you soon.
Email
Mobile/WhatsApp
Name
Company Name
Message
0/1000
Products
Home> Products

Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz

Product Description
Work with confidence with the oscilloscope that offers simplified testing, more insight, faster electro-mechanical
troubleshooting, and comes with 40 MHz of bandwidth. Conveniently measures voltage, current, power waveforms and automatically displays critical numerical readings.
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz supplier
Fluke 125B 40 MHz, 2-Channel, 40 MS/s Industrial ScopeMeter Hand-Held Oscilloscope with Bus Health and Fluke Connect Compatibility
* 125B/NA Industrial ScopeMeter Handheld Oscilloscope with Bus Health Test 40MHz (North America)
* Dual-input digital oscilloscope and multimeter
* 40 MHz or 20 MHz oscilloscope bandwidth
* Two 5,000-count true-rms digital multimeters
* Connect-and-View™ trigger simplicity for hands-off operation
* IntellaSet™ technology automatically and intelligently adjusts numerical readout based on the measured signal
* Dual-input waveform and meter reading recorder for trending data over extended periods
* Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
* Shielded test leads for oscilloscope, resistance and
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz manufacture

Fluke 125B - Industrial ScopeMeter Handheld Oscilloscope with Bus Health Test 40MHz (North America)
* 40 MHz or 20 MHz Oscilloscope Bandwidth
* Shielded test leads for oscilloscope, resistance and continuity measurements
* Resistance, continuity, diode and capacitance meter measurements
* Power measurements (W, VA, VAR, PF, DPF, Hz)
.
Simplified testing, more insight and faster electro-mechanical troubleshooting
The compact ScopeMeter® 120B Series, is the rugged oscilloscope solution for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. It’s a truly integrated test tool, with oscilloscope, multimeter and high-speed recorder in one easy-to-use instrument. The ScopeMeter 120B Series also integrates with Fluke Connect® mobile app and FlukeView® for ScopeMeter software to enable further collaboration, data analysis and archiving of critical test information.
The 120B Series Industrial ScopeMeter test tools include innovative functions designed to help technicians troubleshoot faster and get the answers they need to keep their systems up and running. Display waveforms with Connect-and-View™ trigger and setup technology and automatically view related numerical measurements using Fluke IntellaSet™ technology, all without making manual measurement adjustments. With Recorder Event Detect capabilities, elusive intermittent events are captured and logged for easy viewing and analysis.
What's included with the Fluke 125B
* Oscilloscope
* 2 x Shielded Test Leads with Ground Leads
* Test Lead
* Hook Clips
* Banana to BNC Adapter
* Voltage Probe
* AC Current Clamp
* USB Angled Adapter
* WiFi USB Adapter
* Li-Ion Battery Pack
* Charger/Power Adapter
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz details
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz details
Specification
Oscilloscope Mode (Vertical)
Frequency Response - DC Coupled
Without probes and test leads (with BB120): DC to 40 MHz (-3 dB)
With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)
With VP41 10:1 probe: DC to 40 MHz (-3 dB)
Frequency Response - AC Coupled (LF Roll Off)
Without probes and test leads: <10 Hz (-3 dB)
With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB)
With VP41 10:1 probe: <10 Hz (-3 dB)
Rise Time, Excluding Probes, Test Leads
<8.75 ns
Input Impedance
Without probes and test leads: 1 MΩ/20 pF
With BB120: 1 MΩ/24 pF
With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF
With VP41 10:1 probe: 5 MΩ/15.5 pF
Sensitivity
5 mV to 200 V/div
Analog Bandwidth Limiter
10 kHz
Display Modes
A, -A, B, -B
Maximum Input Voltage A and B
Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage
With BB120: 600 Vrms
Maximum Floating Voltage, from any Terminal to Ground
600 Vrms CAT IV, 750 Vrms up to 400 Hz
Oscilloscope Mode (Horizontal)
Scope Modes
Normal, single, roll
Ranges (Normal)
Equivalent sampling: 10 ns to 500 ns/div
Real time sampling: 1 μs to 5 s/div
Single (real time): 1 μs to 5 s/div
Roll (real time): 1 s to 60 s/div
Sampling Rate (for Both Channels Simultaneously)
Equivalent sampling (repetitive signals): up to 4 GS/s
Real time sampling 1 μs to 60 s/div: 40 MS/s
Trigger
Screen Update
Free run, on trigger
Source
A, B
Sensitivity A and B
At DC to 5 MHz: 0.5 divisions or 5 mV
At 40 MHz: 1.5 divisions
At 60 MHz: 4 divisions
Slope
Positive, negative
Advanced Scope Functions
Display Modes
Normal: Captures up to 25 ns glitches and displays analog-like persistence waveform
Smooth: Suppresses noise from a waveform
Glitch off: Does not capture glitches between samples
Envelope: Records and displays the minimum and maximum of waveforms over time
Auto Set (Connect-and-View)
Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user
adjustment of amplitude, time base, or trigger level
Input A and B
DC Voltage (V DC)
Ranges: 500 mV, 5, 50, 500, 750 V
Accuracy: ±(0.5% +5 counts)
Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz
Full scale reading: 5000 counts
True RMS Voltages (V AC and V AC+DC)
Ranges: 500 mV, 5, 50, 500, 750 V
Accuracy for 5 to 100% of range (DC coupled)
DC to 60 Hz (V AC + DC): ±(1% +10 counts)
1 to 60 Hz (V AC): ±(1% +10 counts)

Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts)
DC rejection (only V AC): >50 dB
Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz
Full scale reading: 5000 counts, reading is independent of any signal crest factor
Peak
Modes: Maximum peak, minimum peak, peak-to-peak
Ranges: 500 mV, 5, 50, 500, 2200 V
Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale
Full scale reading: 500 counts
Frequency
Ranges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 70 MHz
Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset
Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts)
Full scale reading: 10,000 counts
RPM
Maximum reading: 50 kRPM
Accuracy: ±(0.5% +2 counts)
Duty Cycle
Range: 2 to 98%
Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset
Pulse Width
Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset
Full scale reading: 1000 counts
Amperes
With current clamp
Ranges: same as V DC, V AC, V AC+DC, or peak
Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA
Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty)
Decibel
0 dBV: 1 V
0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω
dB on V DC, V AC, or V AC+DC
Full scale reading; 1000 counts
Crest Factor
Range: 1 to 10
Full scale reading: 90 counts
Phase
Modes: A to B, B to A
Range: 0 to 359°
Resolution: 1°
Power
Configurations: 1 phase/3 phase 3 conductor balanced loads (3 phase: fundamental component only, AUTOSET mode only)
Power factor (PF): Ratio between watts and VA range - 0.00 to 1.00
Watt: RMS reading of multiplying corresponding samples of input A (volts) and input B (amperes); Full scale reading: 999 counts
VA: Vrms x Arms; Full scale reading: 999 counts
VA reactive (var): √((VA)2-W2); Full scale reading: 999 counts
Vpwm
Purpose: To measure on pulse width modulated signals, like motor drive inverter outputs
Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the
fundamental frequency
Accuracy: As Vrms for sine wave signals
Input A to Common
Ohm
Ranges: 50, 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ
Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts)
Full scale reading: 50 Ω to 5 MΩ - 5000 counts; 30 MΩ - 3000 counts
Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges
Open circuit voltage: <4 V
Common Continuity (Cont)
Beep: <(30 Ω ±5 Ω) in 50 Ω range
Measurement current: 0.5 mA
Detection of shorts of: ≥1 ms
Common Diode
Measurement voltage: At 0.5 mA: >2.8 V
At open circuit: <4 V
Measurement current: 0.5 mA
Polarity: + on input A, - on COM
Capacitance (CAP)
Ranges: 50, 500 nF, 5, 50, 500 μF
Full scale reading: 5000 counts
Measurement current: 500 nA to 0.5 mA, increases with increasing ranges
Advanced Meter Functions
Zero Set
Set actual value to reference
AutoHold (on A)
Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of
1 Vpp for AC signals and 100 mV for DC signals
Fixed Decimal Point
Activated by using attenuation keys
Cursor Readout
Sources
A, B
Single Vertical Line
Average, minimum and maximum readout
Average, minimum, maximum and time from start of readout (in ROLL mode; instrument in HOLD)
Minimum, maximum and time from start of readout (in RECORDER mode; instrument in HOLD)
Harmonics values in POWER QUALITY mode
Dual Vertical Lines
Peak-peak, time distance and reciprocal time distance readout
Average, minimum, maximum and time distance readout (in ROLL mode; instrument in HOLD)
Dual Horizontal Lines
High, low and peak-peak readout
Rise or Fall Time
Transition time, 0%-level and 100%-level readout (manual or auto leveling; auto leveling only possible in single channel mode)
Accuracy
As oscilloscope accuracy
Recorder
Meter Readings
Measurement speed: Maximum 2 measurements
Record size (minimum, maximum, average): 2 M readings for 1 channel
Recorded time span: 2 weeks
Maximum number of events: 1024
Waveform Record
Maximum sample rate: 400 K samples
Size internal memory: 400 M samples recorded time
Span internal memory: 15 minutes at 500 μs/div - 11 hours at 20 ms/div
Record size SD card: 1.5 G samples
Recorded time span SD card: 11 hours at 500 μs/div - 14 days at 20 ms/div
Maximum number of events: 64
Power Quality
Readings
Watt, VA, var, PF, DPF, Hz
Watt, VA, Var Ranges (Auto)
250 W to 250 MW, 625 MW, 1.56 GW
When selected: total (%r) ±(2% + 6 counts)
When selected: fundamental (%f) ±(4% + 4 counts)
DPF
0.00 to 1.00
PF
0 to 1, ±0.04
Frequency Range
10 Hz to 15 kHz
40 to 70 Hz
Number of Harmonics
DC to 51
Readings/Cursor Readings
(Fundamental 40 to 70 Hz)
Vrms/Arms /Watt
Each harmonic from fundamental maybe selected for individual readings
Bus Health Tester
AS-i
Subtype: NEN-EN50295
CAN
Subtype: ISO-11898
Interbus S
Subtype: RS-422
Protocol: EIA-422
Modbus
Subtype: RS-232; Protocol: RS-232/EIA-232
Subtype: RS-485; Protocol: RS-485/EIA-485
Foundation Fieldbus
Subtype: H1
Protocol: 61158 type 1, 31.25 kBit
Profibus
Subtype: DP; Protocol: EIA-485
Subtype: PA; Protocol: 61158 type 1
RS-232
Subtype: EIA-232
RS-485
Subtype: EIA-485
General Specifications
Waveform Display
Vertical: 10 div of 40 pixels
Horizontal: 12 div of 40 pixels
Maximum Input Voltage A and B
Direct on input or with leads: 600 Vrms CAT IV for derating
With banana-to BNC adapter BB120: 600 Vrms for derating
Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz
Display
Type: 5.7" color active martrix TFT
Resolution: 640 x 480
Interface
Optically isolated: Transfer screen copies (bitmaps), settings and data
USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows®
Wireless Radio with Adapter
Frequency range: 2412 to 2462 MHz
Output power: <100 mW
Environmental
MIL-PRF-28800F, Class 2
Temperature
Battery operation: 32 to 104°F (0 to 40°C)
Power adapter operation: 32 to 122°F (0 to 50°C)
Storage: -4 to 140°F (-20 to 60°C) non-condensing
Humidity (Operating)
At 32 to 50°F (0 to 10°C): non-condensing
At 50 to 86°F (10 to 30°C): 95%
At 86 to 104°F (30 to 40°C): 75%
At 104 to 122°F (40 to 50°C): 45%
Altitude
Operating at 10,000' (3 km): CAT III 600 V
Operating at 6600' (2 km): CAT IV 600 V
Storage: 40,000' (12 km)
EMC Electromagnetic Compatibility
USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103)
Enclosure Protection
IP51, ref: EN/IEC60529
Safety
General: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V
Memory
Internal memory can store 20 data sets (screen waveform and setup)
Micro SD card slot with optional SD card (maximum size of 32 GB)
Power
External: Via power adapter BC430
Input voltage: 10 to 21 V DC Consumption: 5 W typical
Input connector: 5 mm jack
Internal: Via battery pack BP290
Battery power: Rechargeable Li-Ion 10.8 V
Operating time: 7 hours with 50 % backlight brightness
Charging time: 4 hours with test tool off, 7 hours with test tool on
Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging
Dimensions
10.2 x 5.2 x 2.15" (259 x 132 x 55 mm)
Weight
3.2 lbs (1.4 kg) including battery pack
Packing & Delivery
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz manufacture
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz details
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz details
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz supplier
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz details
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz factory
Company Profile
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz supplier
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz details
Fluke 125B Industrial ScopeMeter Hand-Held Oscilloscope with AC Clamp 40 MHz manufacture
As an important international instrument sales platform, our company has the authorization qualifications of many international first-line brands. Relying on the advanced digital information management platform and international procurement platform, we provide more than 100,000 instruments, industrial MRO products, industrial products and spare parts to global customers. Our business scope: industrial testing, non-destructive testing, gas testing, electrical testing, laboratory testing, water quality testing, environmental testing, medical testing... So far, we have become an important partner of many global top 500 companies and well-known local Chinese companies. Create an efficient supply chain system to provide customers with strong supply guarantee.

Get a Free Quote

Our representative will contact you soon.
Email
Name
Company Name
Message
0/1000
email goToTop